rtd.gif (1412 bytes)

Sensor Scientific, Inc. Platinum Thin Film RTD Elements are fabricated using state-of-the-art thin film processing techniques, resulting in an element of exceptional quality and stability. The wide choice of resistance, tolerance, and size options allows for complete design flexibility.

RTD elements are available with extension leads, and incorporated in complete temperature probe assemblies. Please contact Sensor Scientific for additional information.

 

Available in 100, 500, 1000, and 2000 ohm resistance values
Standard DIN EN 60751, ASTME1137 & non-standard tolerances available
Custom 2, 3, and 4 wire extension leads available
Custom-Engineered Temperature Probe Assemblies

rtd.jpg (10417 bytes)

Assemblies: Generally, thin film RTD elements are incorporated into some type of assembly for protection. Extension leads may be attached via soldering, crimping, brazing or welding. The attachment method must be capable of withstanding the intended maximum operating temperature.

The following precautions must be taken when incorporating the element into an assembly:

  1. Avoid straining the element leads.
  2. The resistance of extension leads must be taken into consideration. The resistance value at 0 Deg. C calibrated 1mm from end of lead wire.
  3. If extension leads are attached via soldering or brazing, all flux residue must be removed.
  4. If elements are encapsulated in a potting compound, insure that the compound will not induce pressure loads, resulting in a strain-gage effect.
Resistance
at 0 Deg. C
ohms
L
Length
mm
W
Width
mm
H
Height
mm
Part
Number
100/1000 1.7 1.25 0.9 PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)A
100/500/1000 2.3 2.1 0.9 PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)B
100/500/1000 3.9 2.1 0.9 PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)C
1000/2000 5.9 2.1 0.9 PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)D
100/500/1000 9.5 1.9 0.9 PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)E

Part numbers - example:
RTD 1000 Ohm at 0 C, Class B, Temp -70 to 500 C, Size 1.7 x 1.25 x 0.9 mm = Part No.

P100BMA

PXXredcrcle.gif (120 bytes)redsqure.gif (77 bytes)A
Resistance value at 0°C calibrated 1mm from end of lead wire.

redcrcle.gif (120 bytes) - Tolerance
0B = DIN Class B
03 = 1/3 DIN Class B 0 to +150 Deg C
0A = Class A -50 to +300 Deg C
XX - Resistance Value
100 ohm XX=01
500 ohm XX=05
1000 ohm XX=10
2000 ohm XX=20

redsqure.gif (77 bytes) Temperature Range
* L = -50 to + 400 Deg C
M= -70 to + 500 Deg C
* H= -70 to + 600 Deg C

*Check for Availability