Interchangeable Chip Thermistors
|
 
|
|


Sensor Scientific interchangeable chip thermistors are ideally suited for applications requiring a high-precision temperature sensor, without a high cost. Interchangeability eliminates the burden of individual calibration. Units are available in resistance values from 2k ohms to 100k ohms @ 25°C. The available resistance vs. temperature curves (SSi curves C, D, E & Y) are industry-standard. Interchangeable wafer thermistors are widely used in the medical, automotive, aerospace, HVAC, marine electronic, and instrumentation industries in a variety of temperature measurement, control, and compensation applications. If a standard unit does not meet your needs, customized tolerances, resistance values, temperature ranges, and termination options are available. Design assistance is also available. |
|
 |
| FEATURES: |
| • |
HIGH ACCURACY |
| • |
HIGH STABILITY |
| • |
INTERCHANGEABLE FROM 0°C TO 70°C |
| OPTIONS: |
| • |
CUSTOMIZED LEAD AND TERMINATION |
| • |
CONFIGURATIONS NON-STANDARD RESISTANCE VALUES |
| • |
NON-STANDARD TOLERANCES |
| • |
NON-STANDARD OPERATING RANGES |
| • |
NON-STANDARD RESISTANCE VS. TEMPERATURE CURVES |
|
Resistance
@ 25 Deg C
ohms |
PART NUMBER |
R. vs. Temp.
Curve |
Lead
Diameter
inches |
Lead
Length inches |
±0.2 Deg C
tolerance |
±0.5 Deg C
tolerance |
±1.0 Deg C
tolerance |
| 2000 |
WM202C |
WN202C |
WP202C |
C |
0.0126 |
1.5 min. |
| 2252 |
WM222C |
WN222C |
WP222C |
C |
0.0126 |
1.5 min. |
| 3000 |
WM302C |
WN302C |
WP302C |
C |
0.0126 |
1.5 min. |
| 4000 |
WM402C |
WN402C |
WP402C |
C |
0.0126 |
1.5 min. |
| 5000 |
WM502C |
WN502C |
WP502C |
C |
0.0126 |
1.5 min. |
| 10000 |
WM103C |
WN103C |
WP103C |
C |
0.0126 |
1.5 min. |
| 10000 |
WM103Y |
WN103Y |
WP103Y |
Y |
0.0126 |
1.5 min. |
| 30000 |
WM303D |
WN303D |
WP303D |
D |
0.0126 |
1.5 min. |
| 30000 |
WM303E |
WN303E |
WP303E |
E |
0.0126 |
1.5 min. |
| 50000 |
WM503D |
WN503D |
WP503D |
D |
0.008 |
2.0 min. |
| 100000 |
WM104D |
WN104D |
WP104D |
D |
0.008 |
2.0 min. |
|
Dissipation Constant: 1.5 mW/°C Typ. in still air
Time Constant: 10 sec. Typ. in still air
|
|
"The information contained herein is believed to be accurate. The user, however, should verify the suitability of a particular product for a specific application. Sensor Scientific, Inc. does not warrant the accuracy of this information, and disclaims any liability with respect to its use"